Electrical Rating
80
Electrical Rating
The enclosure input current is 100 - 240 VAC, 10 - 5
Amps, 50/60Hz
Temperature
Operating Temperature: 0
o
C to 40
o
C
Temperature Storage: -40
o
C to +70
o
C
Maximum rate of temperature change: 20
o
C per hour
Humidity
Relative Humidity Operating: 5% to 95%, non-condensing
Relative Humidity Storage: 5% to 95%, non-condensing
Altitude
Altitude Operating: -50 to 10,000 feet
Altitude Storage: -50 to 40,000 feet
Operational Shock
Half sine shock: 5G half sine shock with a pulse duration
of 11 milliseconds or less. No permanent damage will occur
at or below this level.
Operational Vibration
The operational vibration supported is 0.2G @ 5Hz to
400Hz. No permanent damage will occur at or below these
levels.